If the harness is a possible issue I was considering this.
The pump has a 12v feed when the ignition is turned on. The ECU then turns the earth on until the pump is up to pressure then turns it off. When the ECU gets a signal from the ignition sensor it turns the earth on again so the engine will run.

Somebody rewired it then or is the test meter leads connected wrong as normally the pumps Earth goes directly to earth and the 12 volt feed is supplied by one of the engine management relays with the status of the relay controlled by the ECU, the same relay should also put 12 volts on to the coils at the same time as putting it onto the pump