Two circuit alarm
One circuit usually taps into the Fuel pump circuit and the other into the starter circuit. Each circuit is seperate and either controlled by relays or power transistors inside the alarm.
Most likely the Meta uses Relays and one of them has failed, weak electromagnetic field or carbonised contacts or faulty solder joint or alarm wiring damaged