Mood: MT Meglomaniac
House lighting - wiring question

Up my stairs and landing there is not much natural daylight, so as part of the last bit of renovation my old house needs I've put in a whole bunch of those mains voltage halogen downlighters (10 of them in all).

Fine in the daytime, but a bit bright at night. So, I now want to fit a dimmer switch for them. .

I took the mains supply for the lights from the junction box (not the ceiling rose) that fed the original pendant light and then did away with the pendant. The light switches are the usual hallway/landing two way affairs with one switch at the top and one at the bottom of the stairs.

I had a quick look in Homebase (I only had 10 minutes before I needed to be somewhere else), but none of the dimmer switches had much info on them except for an installation card that was folded up in the pack that you couldn't read.

So, a couple of questions. Can you get dimmer switches that work in a two way circuit? I would only want one switch to be the dimmer. Second, I was fixated by the two-way question and didn't look to see if an ordinary common or garden dimmer can handle 500 watts worth?
Quote+Reply
  #2  
Old 15-Feb-2005, 21:36
748mart 748mart is offline
Registered Forum User
Mille
 
Posts: 268
Join Date: Jul 2001
Dimmers can be found in single or 2 way operation & they are typically rated at about 300watts. I'm sure if you hunt around enough you may find a 2 way one exceeding 500watts.
Quote+Reply
  #3  
Old 15-Feb-2005, 21:49
Felix Felix is offline
Registered Forum User
Ducati Meccanica
 
Posts: 2,467
Join Date: Dec 2001
Mood: Is 112 dB loud enough?? What??
Yes, you can get them for higher wattages but they usually require a deeper back box. Also, if you only fit one dimmer the second (ordinary) switch would likely switch the lights on at full brightness. Go to a local electrical supply merchant.

[Edited on 15-2-2005 by Felix]
Quote+Reply
  #4  
Old 15-Feb-2005, 23:37
KeefyB KeefyB is offline
Registered Forum User
WSB Hero
 
Posts: 7,600
Join Date: May 2002
Mood: Lurkin'.....
I hope you are'nt doing your own wiring now that Part 'P' has come into operation??!!
Yeah you can get dimmers that can handle 500W.As suggested before,try at an Electrical Wholesalers,(plenty in the Bedford area) rather than B&Q,Wickes etc.
If you need a two gang switch for the hall/landing,you may have to buy a "grid" switch.(i.e one ordinary 1 way and one dimmer)These are switches that you can make up to your own needs.You buy the front plate and yolk or grid,then fit in whatever switches you require.Crabtree or MK make these.
Quote+Reply
  #5  
Old 16-Feb-2005, 00:36
rcgbob44's Avatar
rcgbob44 rcgbob44 is offline
Registered Forum User
BSB Star
Bikes: 998s, Jota, KTM 690 Duke
 
Posts: 5,990
Join Date: May 2003
Mood: My Jota goes rumpety rump! & I have my wife exactly where she wants me!
I suggest that you change your 50 watt bulbs for 35 watt ones, you will not notice a great deal opf difference in the light output and you will find it easier to find a dimmer capable of handling 350 watts as opposed to 500 watts.
Quote+Reply
  #6  
Old 16-Feb-2005, 07:39
KeefyB KeefyB is offline
Registered Forum User
WSB Hero
 
Posts: 7,600
Join Date: May 2002
Mood: Lurkin'.....
If you cant be arsed to trawl around the wholesalers,have a look in the Screwfix catalogue,I'm sure they have what you want.
www.screwfix.com
Quote+Reply
  #7  
Old 16-Feb-2005, 09:18
guest1 guest1 is offline
Registered Forum User
Big Twin
 
Posts: 1,173
Join Date: Mar 2008
Quote:
Originally posted by KeefyB
I hope you are'nt doing your own wiring now that Part 'P' has come into operation??!!

Part P permits the changing of fixtures and fittings without the need for a minor works certificate (self certification) or the involvment of a building control officer. So you can go ahead with changing socket fronts/light fittings/switches.
Not withstanding the fact that a qualified electrician would be carrying out the work (?).
I believe that there is a "probation" period upto 25th March, where you must complete any works started prior to 1st January if you are to avoid the Part P "entrapment".

Part P Q&A

KeefyB - don't run the lamps at dimmed all of the time, you will need to run them at full power every now and then just to keep the internal gasses/metals in vapour

Screw Fix 650va dimmer 1 gang 2 way

[Edited on 16-2-2005 by guest1]

[Edited on 16-2-2005 by guest1]
Quote+Reply
  #8  
Old 16-Feb-2005, 11:38
Jools's Avatar
DSC Member Jools Jools is offline
DSC Club Member
BSB Star
 
Posts: 6,930
Join Date: Jul 2002
Mood: MT Meglomaniac
Part P? What the hell is that?

Nope, I'm not a qualified electrician as such, but I used to be a computer systems engineer working on mainframes. That included a lot of work on three phase stuff and complex wiring which I was qualified for....enough to cope with a lighting cicuit methinks, whatever Brussels may have to say about it.

Cheers for your help guys, I think we're sorted
Quote+Reply
  #9  
Old 16-Feb-2005, 18:46
KeefyB KeefyB is offline
Registered Forum User
WSB Hero
 
Posts: 7,600
Join Date: May 2002
Mood: Lurkin'.....
Quote:
Originally posted by guest1
Quote:
Originally posted by KeefyB
I hope you are'nt doing your own wiring now that Part 'P' has come into operation??!!

Part P permits the changing of fixtures and fittings without the need for a minor works certificate (self certification) or the involvment of a building control officer. So you can go ahead with changing socket fronts/light fittings/switches.
Not withstanding the fact that a qualified electrician would be carrying out the work (?).
I believe that there is a "probation" period upto 25th March, where you must complete any works started prior to 1st January if you are to avoid the Part P "entrapment".

Part P Q&A

KeefyB - don't run the lamps at dimmed all of the time, you will need to run them at full power every now and then just to keep the internal gasses/metals in vapour

Screw Fix 650va dimmer 1 gang 2 way

[Edited on 16-2-2005 by guest1]

[Edited on 16-2-2005 by guest1]
Yes mate,I know.(I am a sparks!)
Its Jools with the dimmer query.
Quote+Reply
  #10  
Old 16-Feb-2005, 18:53
guest1 guest1 is offline
Registered Forum User
Big Twin
 
Posts: 1,173
Join Date: Mar 2008
Apologies KeefyB, I'll get me coat (and a pair of glasses for when next on board).
There is no emoticon for blind as a bat - would it just be a circle wiv a mouth??
Quote+Reply
  
Thread Tools
Display Modes
Postbit Selector
Switch to Vertical postbit Use Vertical Postbit

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Recent Posts - Contact Us - DSC Home - Archive - Top
Powered by vBulletin 3.5.4 - Copyright © 2000 - 2025, Jelsoft Enterprises Ltd. - © Ducati Sporting Club UK - All times are GMT +1. The time now is 23:44.